Skip to main content

Smart Grid Fault Indicator Unit

Overview

Description

This grid fault current indicator is an example of a low-power design system that shows customers the most efficient approach for system implementation.

The fault indicator unit uses Renesas’ high-performance RA2 MCU series, which includes a 16-bit SAR ADC, 24-bit sigma-delta ADC, COMP, system control, touch control, super low power, etc. In the data collection unit, the RL78/G13 is a standard function MCU with low power and an abundant lineup for general-purpose applications. Bluetooth® is used for communication between the two boards. Combined with Renesas’ high-performance power and analog solutions, this system can minimize idle quiescent current. This helps save power consumption during standby states.

System Benefits:

  • Low quiescent power MCUs for optimized efficiency
  • High-performance analog devices for accurate system monitoring

Comparison

Applications

Block Diagram

Select a block to discover products for your design

Test This Board Remotely

Available on Lab on the Cloud, use our PC-based GUI to instantly start configuring and testing designs in our virtual lab, no physical board needed.
4:3 ratioSheet.1Sheet.2Sheet.3Sheet.4CN071CN071CN071ShuntSheet.11Sheet.12Sheet.13Battery ChargerBattery ChargerBattery ChargerVoltage ReferenceVoltage ReferenceVoltage ReferenceVoltage SupervisorVoltage SupervisorVoltage SupervisorLED DriverLED DriverLED DriverBuck ConverterBuck ConverterBuck ConverterBoost ConverterBoost ConverterBoost ConverterGround (earth)Sheet.40Sheet.41Sheet.42Sheet.43Sheet.44Sheet.45Diode.316Sheet.47Sheet.48Sheet.49Capacitor Non-polarizedSheet.53Sheet.54Battery Li-ionSheet.56Sheet.57Label Text 10pt.70LI-IONLI-IONGround (earth).59Sheet.60Sheet.61Sheet.62Sheet.63Transformer.64Line.841Line.842Shunt.67Sheet.68Sheet.69Sheet.70DiodeSheet.72Sheet.73Sheet.74Diode.75Sheet.76Sheet.77Sheet.78TumblerTumblerTumblerLEDLEDLEDBluetoothTransformerTransformerTransformer3.3V3.3V3.3VSheet.101Power Line 3KV-35KVPower Line 3KV-35KVPower Line 3KV-35KVSheet.104Sheet.105Sheet.107Sheet.108Sheet.109Sheet.110Sheet.111Sheet.112Sheet.114Sheet.115Sheet.116Sheet.117Sheet.118Sheet.119Sheet.120Sheet.121Sheet.122Sheet.123Sheet.124Sheet.125Sheet.126Sheet.127Sheet.128Sheet.129Sheet.130Transformer.141Line.841Line.842Sheet.144Sheet.145Connector 1.163Connector 1.163.149Connector 1.163.150Connector 1.163.151Connector 1.163.152Connector 1.163.153 TransformerTransformerTransformer4.5V4.5V4.5VSheet.159MCUMCUMCU16-bit ADC16-bit ADC16-bitADCUARTUARTUARTGPIOGPIOGPIO UARTUARTUARTBuck-Boost RegulatorBuck-Boost RegulatorBuck-Boost RegulatorOp AmpOp AmpOp Amp
Exiting Interactive Block Diagram

Support

Support Communities

Support Communities

Get quick technical support online from Renesas Engineering Community technical staff.
Browse Articles

Knowledge Base

Browse our knowledge base for helpful articles, FAQs, and other useful resources.
Submit a Ticket

Submit a Ticket

Need to ask a technical question or share confidential information?