Features
- High isolation voltage (BV = 5000Vrms)
- High collector to emitter voltage (VCEO = 40V)
- Guaranteed maximum switching speed
(toff ≤ 25μs @ IF = 5mA, VCC = 5V, RL = 5kΩ) - High-speed switching
(ton = 15μs TYP. @ IF = 5mA, VCC = 5V, RL = 5kΩ)
(toff = 15μs TYP. @ IF = 5mA, VCC = 5V, RL = 5kΩ) - Embossed tape product: PS2514L-1-F3: 2000 pcs/reel
- Pb-Free product
- Safety standards
- UL approved: No. E72422
- CSA approved: No. CA 101391 (CA5A, CAN/CSA-C22.2 60065, 60950)
- CQC approved: CQC11001056759/CQC11001056758 CQC11001056865/CQC11001057073
- VDE approved: DIN EN 60747-5-2 (VDE 0884 Part2); No. 40008862 (Option)
Description
The PS2514-1 and PS2514L-1 are optically coupled isolators containing a GaAs light emitting diode and an NPN silicon phototransistor, enabling relatively high switching speed with a high load resistor of several kΩ. The PS2514-1 is in a plastic DIP (Dual In-line Package) and the PS2514L-1 is a lead bending type (Gull-wing) for surface mount.
Parameters
| Attributes | Value |
|---|---|
| Channels (#) | 1 |
| VCEO max (mA) | 40 |
| IC max (mA) | 20 |
| Isolation Voltage (Vrms) | 5000 |
| CTR (min)% | 50 |
| CTR (Max)% | 200 |
| IF at CTR (mA) | 5 |
| VCE at CTR (V) | 5 |
| SW ton Typ. (µs) | 15 |
| SW toff Typ. (µs) | 15 |
| Creepage Distance (mm) | 7 |
| Safety Standard UL (UL1577) | Approved |
| Safety Standard VDE (EN IEC 60747-5-5) | Approved |
| Safety Standard CSA (CAN/CSA C22.2 62368-1) | Approved |
| Safety Standard CQC (GB4943.1) | Approved |
Application Block Diagrams
|
|
Level 2 EV Charger
Modular EVSE system with advanced connectivity for efficient EV charging and management.
|
|
|
3-Phase Smart Electric Meter
3-phase smart meter with remote data access and high-voltage operation for heavy loads.
|
|
|
1-Phase Static Meter
Low-power 1-phase static meter optimized for basic electronic metering needs.
|
Additional Applications
- Power supplies
- Factory automation (FA) equipment
- Electronic electricity meters