Features
- IO-Link stack embedded
- Support Smart Sensor Profile in COM3 mode
- Firmware update via IO-Link
- Calibration via IO-Link
- Accurate system clock, no crystal needed
- Accommodates nearly all resistive bridge sensors in various configurations
- On-chip temperature sensor
- External temperature sensing supported
- Programmable 16-bit digital-to-analog converter and output (supporting "True Zero Volts (0V)" output)
- Wide operational temperature and supply range
- On-chip voltage regulators for sensor supply, and IC operation
- Programmable sensor signal conditioning math core
- Reprogrammable, non-volatile memory (NVM)
- On-chip diagnostics
Description
The ZSSC3286 is a dual path sensor signal conditioning IC (SSC) for highly accurate amplification, digitization, and sensor-specific correction of sensor signals. The ZSSC3286 supports IO-Link connectivity with an integrated IO-Link stack running the IO-Link Smart Sensor Profile for digital measuring and switching sensors. The device is suitable for bridge and half-bridge sensors, as well as external voltage source elements. Digital compensation of the sensor offset, sensitivity, temperature drift, and non-linearity is accomplished via a 32-bit Arm® based math core running a correction algorithm with calibration coefficients stored in a non-volatile, reprogrammable memory. The programmable, integrated sensor front-end allows optimally applying various sensors for a broad range of applications.
Parameters
| Attributes | Value |
|---|---|
| Function | Resistive SSC |
| Automotive Qual. | No |
| Supply Voltage (V) | 1.8 - 48 |
| Input Type | Dual-bridge |
| Interface | I2C, SPI, Alarm, Ratiometric Voltage, Absolute Voltage, Current Loop, OWI, PWM, 2xPDM, 2xPWM |
| Adj. Analog Gain | 1.32 - 540 |
| Resolution (bits) | 24 |
| Sample Rate Max (KHz) | 2.91 |
| Temp. Range (°C) | -40 to 125°C, 0 to 70°C |
Application Block Diagrams
| IO-Link Sensors This system enables smart sensor control via IO-Link communication. |
Additional Applications
- Industrial sensors with IO-Link interface
- Enables smart, digital sensors for energy-efficient solutions
- Pressure, flow, and level sensing
- Factory automation
- Process automation
- Pressure
- Flow
- Load
- Temperature
Complete Your Design
Explore complementary products to elevate your design
| Part Number | Status | Samples | Stock | Package | Budgetary Price (USD) | Lead Count (#) | Carrier Type | Moisture Sensitivity Level (MSL) | Pkg. Dimensions (mm) | Pb (Lead) Free | Pb Free Category | Temp. Range (°C) | Country of Assembly | Country of Wafer Fabrication |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZSSC3286CI1B | Active | N/A | Out of Stock | WAFER | 1ku | $2.88 | 0 | Wafer | 1 | 0.0 x 0.0 x 0.0 | Yes | e3 Sn | -40 to 125°C | ||
| ZSSC3286CI1D-ES | Active | N/A | Out of Stock | WAFER | 0 | WFP | 1 | 0.0 x 0.0 x 0.0 | Yes | e3 Sn | 0 to 70°C | TAIWAN | ||
| ZSSC3286CI3R | Active | Available | Out of Stock | VFQFPN | 1ku | $3.28 | 40# | Reel | 1 | 5.0 x 5.0 x 0.9 | Yes | e3 Sn | -40 to 125°C | ||
| ZSSC3286CI8R | Active | Available | Out of Stock | WLCSP | 1ku | $3.28 | 48# | Reel | 1 | 3.61 x 3.24 x 0.6 | Yes | e3 Sn | -40 to 125°C | ||
| ZSSC3286BI3R | Obsolete | N/A | In Stock | VFQFPN | 1ku | $3.28 | 40# | Reel | 1 | 5.0 x 5.0 x 0.9 | Yes | e3 Sn | -40 to 125°C | TAIWAN | TAIWAN |
| ZSSC3286BI8R | Obsolete | N/A | Out of Stock | WLCSP | 1ku | $3.28 | 48# | Reel | 1 | 3.61 x 3.24 x 0.6 | Yes | e3 Sn | -40 to 125°C | MALAYSIA | TAIWAN |
Complete Your Design
Explore complementary products to elevate your design
- DatasheetZSSC3286 DatasheetRECOMMENDEDPDF 6.01 MB R33DS0047ED0100 Rev.1.00 Jul 10, 2025The ZSSC3286 is a dual-path sensor signal conditioner (SSC) IC designed for highly accurate amplification, digitization, and sensor-specific correction of sensor signals. It supports IO-Link connectivity with an integrated IO-Link stack running the IO-Link Smart Sensor Profile for digital measurement and switching sensors.
- Application NotePDF 2.25 MB Mar 25, 2025AI-generated Summary: Two reference designs for an IO-Link sensing solution combine the ZSSC3286 dual-channel resistive sensor signal conditioner and the RH4Z2501 single-channel IO-Link physical layer transceiver. The designs focus on circuit schematics and PCB layouts optimized for EMC performance and thermal management. Both designs pass IO-Link conformance tests including functional and environmental tests such as ESD, EMC, burst, surge, and radiated emissions. Key design guidelines include short communication tracks, separation of high and low voltage areas, solid ground and power planes, via stitching, and proper capacitor placement. The document details two package types: QFN/DFN and WLCSP, with PCB stack-ups and layer layouts provided. PCB design files include BOM, schematics, and Gerber files.
- White PaperPDF 477 KB Sep 10, 2024IO-Link enables intelligent, bidirectional communication for industrial sensors and actuators, improving diagnostics, remote configuration, and interoperability. The ZSSC3286 integrates an IO-Link stack with Smart Sensor Profile, offering dual-channel signal conditioning, calibration, and flexible outputs. This solution simplifies design, reduces part count, and enhances efficiency in industrial automation systems.
- DatasheetZSSC3286 DatasheetRECOMMENDEDPDF 6.01 MB R33DS0047ED0100 Rev.1.00 Jul 10, 2025The ZSSC3286 is a dual-path sensor signal conditioner (SSC) IC designed for highly accurate amplification, digitization, and sensor-specific correction of sensor signals. It supports IO-Link connectivity with an integrated IO-Link stack running the IO-Link Smart Sensor Profile for digital measurement and switching sensors.
Recommended Documents (1)
- DatasheetZSSC3286 DatasheetRECOMMENDEDPDF 6.01 MB R33DS0047ED0100 Rev.1.00 Jul 10, 2025The ZSSC3286 is a dual-path sensor signal conditioner (SSC) IC designed for highly accurate amplification, digitization, and sensor-specific correction of sensor signals. It supports IO-Link connectivity with an integrated IO-Link stack running the IO-Link Smart Sensor Profile for digital measurement and switching sensors.
Datasheets (1)
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
- Application NotePDF 2.25 MB Mar 25, 2025AI-generated Summary: Two reference designs for an IO-Link sensing solution combine the ZSSC3286 dual-channel resistive sensor signal conditioner and the RH4Z2501 single-channel IO-Link physical layer transceiver. The designs focus on circuit schematics and PCB layouts optimized for EMC performance and thermal management. Both designs pass IO-Link conformance tests including functional and environmental tests such as ESD, EMC, burst, surge, and radiated emissions. Key design guidelines include short communication tracks, separation of high and low voltage areas, solid ground and power planes, via stitching, and proper capacitor placement. The document details two package types: QFN/DFN and WLCSP, with PCB stack-ups and layer layouts provided. PCB design files include BOM, schematics, and Gerber files.
- White PaperPDF 477 KB Sep 10, 2024IO-Link enables intelligent, bidirectional communication for industrial sensors and actuators, improving diagnostics, remote configuration, and interoperability. The ZSSC3286 integrates an IO-Link stack with Smart Sensor Profile, offering dual-channel signal conditioning, calibration, and flexible outputs. This solution simplifies design, reduces part count, and enhances efficiency in industrial automation systems.
Application Notes & White Papers (2)
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
No Results Found.
Make sure all keywords are spelled correctly.
Try fewer, different, or more general terms to vary your search.
If you have filters applied, consider deselecting some to broaden your results.
- Search our extensive knowledgebase, designed to help customers with their FAQs.
- Get help from our expert Renesas technical staff and community on our support forums.
Renesas Boards & Kits
IO-Link Ready Dual-Channel Resistive Sensor Signal Conditioner IC Evaluation Kit
The ZSSC3286 evaluation kit provides the hardware needed for the configuration, calibration, and evaluation of the ZSSC3286 sensor signal conditioner (SSC) IC. The user's PC can communicate via USB with the ZSSC3286 IC socketed on the ZSSC3286 evaluation board via IO-Link, using the included... Read More