Skip to main content
Renesas Electronics Corporation - June is Pride Month, a month to raise awareness of the rights and the culture of the LGBTQ+ community

Features

  • 10 ns read/write cycle time
  • Read and Write Clocks can be independent
  • Dual-Ported zero fall-through time architecture
  • Empty and Full Flags signal FIFO status
  • Programmable Almost-Empty and Almost-Full flags can be set to any depth
  • Programmable Almost-Empty and Almost-Full flags default to Empty+7, and Full-7, respectively
  • Output enable puts output data bus in high-impedance state
  • Available in 32-pin PLCC and 32-pin TQFP packages
  • Industrial temperature range (–40C to +85C) is available

Description

The 72251SyncFIFO™ is a 8K x 9 First-In, First-Out memory with clocked read and write controls. This FIFO is useful for a wide variety of data buffering needs such as graphics, local area networks and interprocessor communication. These FIFOs have 9-bit input and output ports. The Read Clock can be tied to the Write Clock for single clock operation or the two clocks can run asynchronous of one another for dual-clock operation.

Part NumberStatusSamplesStockPackageLead Count (#)Temp. GradePb (Lead) FreeCarrier Type
72251L10JObsoleteN/AOut of StockPLCC32#CNoTube
72251L10J8ObsoleteN/AOut of StockPLCC32#CNoReel
72251L10PFObsoleteN/AOut of StockTQFP32#CNoTray
72251L10PF8ObsoleteN/AOut of StockTQFP32#CNoReel
72251L10PFGObsoleteN/AOut of StockTQFP32#CYesTray
72251L10PFG8ObsoleteN/AOut of StockTQFP32#CYesReel
72251L15JObsoleteN/AOut of StockPLCC32#CNoTube
72251L15J8ObsoleteN/AOut of StockPLCC32#CNoReel
72251L15JGIObsoleteN/AOut of StockPLCC32#IYesTube
72251L15JGI8ObsoleteN/AOut of StockPLCC32#IYesReel
72251L15JIObsoleteN/AOut of StockPLCC32#INoTube
72251L15JI8ObsoleteN/AOut of StockPLCC32#INoReel
72251L15PFObsoleteN/AIn StockTQFP32#CNoTray
72251L15PF8ObsoleteN/AOut of StockTQFP32#CNoReel
72251L15PFGIObsoleteN/AOut of StockTQFP32#IYesTray
72251L15PFGI8ObsoleteN/AOut of StockTQFP32#IYesReel
72251L15PFIObsoleteN/AOut of StockTQFP32#INoTray
72251L15PFI8ObsoleteN/AOut of StockTQFP32#INoReel
72251L25JObsoleteN/AOut of StockPLCC32#CNoTube
72251L25J8ObsoleteN/AOut of StockPLCC32#CNoReel
72251L25JIObsoleteN/AOut of StockPLCC32#INoTube
72251L25JI8ObsoleteN/AOut of StockPLCC32#INoReel
72251L25PFObsoleteN/AOut of StockTQFP32#CNoTray
72251L25PF8ObsoleteN/AOut of StockTQFP32#CNoReel
72251L25PFIObsoleteN/AOut of StockTQFP32#INoTray
72251L25PFI8ObsoleteN/AOut of StockTQFP32#INoReel

Support Communities

  1. Observer scan only one channel

    Hi, I have two devices. One broadcaster and one observer. The problem is that the observer seems scan only one channel (37). If I set the broadcaster to advert on 38 or/and 39, the observer doesn't receive any reports. In the same time, my android table receive ...

    Dec 10, 2016
Support Communities

Support Communities

Get quick technical support online from Renesas Engineering Community technical staff.
Browse Articles

Knowledge Base

Browse our knowledge base for helpful articles, FAQs, and other useful resources.
Submit a Ticket

Submit a Ticket

Need to ask a technical question or share confidential information?