Skip to main content
Renesas Electronics Corporation

Description

The 32195 Group is supported only for customers who have already adopted these products. The RX63T Group is recommended for new designs.

Part NumberStatusSamplesStockRoHSPackageBit SizeRAM (KB)Lead Count (#)Supply Voltage (V)Operating Freq (Max) (MHz)CPURTCLVD or PVDDMATimerPWMADCCAN (ch)EthernetTemp. Range (°C)
M32195F4TFP#U4ObsoleteN/AOut of StockRoHS:EN
RoHS:JA
LFQFP3232KB144#3 - 5160MHzM32R-FPUNoNoNo16-bit x 31-ch, 32-bit x 8-chNo10-bit x 16-ch2No-40 to +85
M32195F4UFP#U4ObsoleteN/AOut of StockRoHS:EN
RoHS:JA
LFQFP3232KB144#3 - 5160MHzM32R-FPUNoNoNo16-bit x 31-ch, 32-bit x 8-chNo10-bit x 16-ch2No-40 to +105
M32195F4VFP#U4ObsoleteN/AOut of StockRoHS:EN
RoHS:JA
LFQFP3232KB144#3 - 5128MHzM32R-FPUNoNoNo16-bit x 31-ch, 32-bit x 8-chNo10-bit x 16-ch2No-40 to +125

Support Communities

  1. Timers

    Timer Pulse Unit PART NO: RZ/T1 I am using 2 timers pulse units TPU0 and TPU9. TPU0 for generating interrupt after every 10ms. I am toggling the LED after every 10ms to check whether code is working fine or not. TPU9 is used to check time taken by ...

    Oct 22, 2023
  2. USB CDC HS data rate

    Hello, I'm using the USB High speed module on the SK s7g2 board and the USBX_CDC ACM Device example. I'm using DMA transfer. When I'm looking at the packet send with an USB sniffer and I've notice a lot of NAK response from the device ...

    Dec 8, 2017

Knowledge Base

  1. Is it okay for emulators not supported by SDI-3 specification to debug?

    If you are not using the trace function or the time measurement function, you will have no problems debugging the 32185/32186 and 32192/32195/32196 Groups. If you are using the trace or time measurement functions, the following restrictions apply. [Usage Restrictions] Compared to results gained ...

    Oct 29, 2007
  2. What is Internal Power Supply Generator (VDC)?

    Internal Power Supply Generator (VDC) is a function that converts 5V and 3.3V, which are input to VCCER (main power supply) pin, to the voltage level for internal use.

    Mar 22, 2017
  3. What's the status of P110-P115 to PWM outputs of TOM and TOU?

    The ports (P110-P115) in relation to the TOM timer and the TOU timer always go to a high-impedance state no matter which mode they are in.

    Mar 22, 2017
Support Communities

Support Communities

Get quick technical support online from Renesas Engineering Community technical staff.
Browse Articles

Knowledge Base

Browse our knowledge base for helpful articles, FAQs, and other useful resources.
Submit a Ticket

Submit a Ticket

Need to ask a technical question or share confidential information?