メインコンテンツに移動
P8620型分散電源ユニット

パッケージ情報

CADモデル: View CAD Model
Pkg. Type: DFN
Pkg. Code: NRG12
Lead Count (#): 12
Pkg. Dimensions (mm): 4.0 x 3.0 x 0.9
Pitch (mm): 0.5

環境及び輸出分類情報

Moisture Sensitivity Level (MSL) 1
Pb (Lead) Free Yes
ECCN (US)
HTS (US)

製品スペック

Pkg. Type DFN
Lead Count (#) 12
Carrier Type Reel
Moisture Sensitivity Level (MSL) 1
Qty. per Reel (#) 4000
Tape & Reel Yes
Qty. per Carrier (#) 0
Pb (Lead) Free Yes
Pb Free Category e3 Sn
Temp. Range (°C) -40 to 85°C
Advanced Features Scalable output current, Automatic multi-phasing
Comm. Interface DIF
Function Distributed Power Unit (DPU)
Input Voltage (Max) (V) 5.5
Input Voltage (Min) (V) 2.97
Input Voltage Range (V) 2.97 - 5.5
Length (mm) 4
MOQ 4000
Output Voltage (V) 0.5V, 3.6V
Outputs (#) 1
Parametric Category Multi-Channel Power Management ICs (PMICs)
Pitch (mm) 0.5
Pkg. Dimensions (mm) 4.0 x 3.0 x 0.9
Reel Size (in) 13
Requires Terms and Conditions Does not require acceptance of Terms and Conditions
Supply Voltage (V) 2.97 - 5.5
Switching Frequency (MHz) 1 - 2
Switching Regulators 1
Thickness (mm) 0.9
Width (mm) 3
掲載 No

説明

P8610は、Gen-2 DPS™対応ホストPMICと組み合わせて使用するパワー・マネージメント・デバイスで、PMICのスタンドアロンコントローラに接続した場合に出力レールを出力します。このデバイスは、ホストPMICによって制御される電流源ユニットとして動作します。最大4台のP8610を並列に使用して、最大29A(パルス)までの負荷電流能力を備えた多相レールを作成できます。

独自の単線式Gen-2 DIF™デジタル・バスは、ホストPMICの降圧コントローラをP8610型分散電源ユニット(DPU)に接続し、制御およびステータス情報を交換します。このデバイスはPMICエコシステムにシームレスに統合されており、ユーザの観点からもわかりやすいです。

P8610のDPUは、ホストPMICを介してユーザによる高度なプログラマブル機能を統合しており、DPUの効率、過渡応答、およびスタンバイ電力を最適化できます。DPUは出力電流測定もサポートしており、セーフティおよび診断機能を備えているため、初期のプロトタイプシステムにおいても簡単にデバッグできます。

P8610は、熱特性が改善された小型の3.0mm×4.0mmの12-DFNパッケージで提供されます。