Overview
Description
The RRH62000 is an Integrated Sensor Module measuring critical air quality parameters such as particulate matter (PM1, PM2.5, PM10), total volatile organic compounds (TVOC), Indoor Air Quality Index (IAQ), estimated carbon dioxide concentration (eCO2), temperature (T), and relative humidity (RH) are combined in a single package. The RRH62000 provides digital outputs for each sensor, which can be measured simultaneously. A six-pin connector provides an easy plug and play interface.
Features
- Simultaneous multi-sensor measurements of all relevant air quality parameters
- Sensor outputs feature:
- Detection of particle sizes from 0.3µm to 10.0µm
- Output mass concentration bins for PM1, PM2.5, and PM10
- Temperature (T) and Relative Humidity (RH)
- Measurement of Total Volatile Organic Compounds (TVOC) concentrations and indoor air quality (IAQ) index according to UBA
- Estimates carbon dioxide level (eCO2)
- Operating temperature ranges from -10°C to 60°C
- Operating humidity ranges up to 90% RH
- Siloxane resistant
- I2C and UART interfaces
- Outline dimensions: 46.6mm × 34.8mm × 12mm
- Qualified according to JEITA ED-4701
Comparison
Applications
Documentation
Datasheet | PDF 1.18 MB | |
End Of Life Notice | PDF 748 KB | |
Technical Brief | ZIP 16.96 MB | |
Guide | PDF 588 KB | |
4 items
|
Design & Development
Boards & Kits
All-in-One Integrated Sensor Module for PM2.5, RHT, TVOC, and eCO2 Detection Evaluation Kit
The RRH62000-EVK simplifies the evaluation of the RRH62000 Integrated Sensor Module. This module measures critical air quality parameters, including particulate matter (PM), total volatile organic compounds (TVOC), Indoor Air Quality Index (IAQ), estimated carbon dioxide concentration (eCO2),
All-In-One Air Quality Pmod Evaluation Board
The RRH62000 evaluation board demonstrates the functionality and performance of the RRH62000 all-in-one air quality sensor. The RRH62000 series is used for measuring critical air quality parameters. The design of the RRH62000 evaluation board is generic so that customers can embed the sensor...
Models
ECAD Models
Schematic symbols, PCB footprints, and 3D CAD models from SamacSys can be found by clicking on the CAD Model links in the Product Options table. If a symbol or model isn't available, it can be requested directly from SamacSys.

Models
Model - Other | ZIP 687 KB | |
1 item
|
Product Options
Applied Filters:
Support
Support Communities
Support Communities
-
How does auto cleaning work on the RRH62000?
In the datasheet it is written that autocleaning is performed after power on. Is it done every time the power is turned on, or does the RRH62000 remember the running time since the last cleaning and follow the interval set in TINTC correctly even if the RRH62000 is only running ...
Feb 20, 2025 -
RRH62000 Connector
I have a RRH62000 board and I can't figure out what this connector is. The docs make a reference to being compatible with the JST GHR series, but the connector on the actual unit (pictured) above seems different.
Sep 1, 2024 -
RRH62000 working principle
Hi, I want to ask if there is an official documentation about the specific working principle of RRH62000. For example, it would be interesting to know if the measurements of PM higher then 2.5 (i.e. PM10) are estimated from the number of PM2.5 counted (like other laser ...
Nov 21, 2024
FAQs
-
RRH62000 - Wiring
Last Updated: 08/29/2024 Question: What connectors are compatible for cabling to interface with the RRH62000-A1V sensor module? Answer: The RRH62000 Sensor Module offers multiple wiring and connector options for interfacing, depending on your specific requirements. Here are some of the available choices: 1. Socket/ ...
Aug 29, 2024 -
RRH62000: Can the sensor be used for both indoor and outdoor air quality monitoring?
The RRH62000 Sensor Module is primarily designed for indoor air quality monitoring, but can be used for limited outdoor applications with proper considerations: Indoor applications:The sensor is well suited for monitoring indoor air quality (IAQ) in environments such as: Homes, offices and schools. Air purifiers, HVAC systems and IoT ...
Dec 18, 2024 -
RRH62000 - Power Cycle / Reset
All settings, such as the moving average, are reset to their default values and should be adjusted if necessary. Upon restart, the gas sensor begins a stabilization process, so the initial TVOC readings will be less accurate until warm-up is complete.