Overview
Description
The ISL94212 Li-ion battery manager IC supervises up to 12 series connected cells. The part provides accurate monitoring, cell balancing and extensive system diagnostics functions. Three cell balancing modes are provided: Manual Balancing mode, Timed Balancing mode and Auto Balance mode. The Auto Balance mode terminates balancing functions when a charge transfer value has been met. The ISL94212 communicates to a host microcontroller via an SPI interface and to other ISL94212 devices using a robust, proprietary, two-wire Daisy Chain system. The ISL94212 is offered in a 64 Ld TQFP package and is specified for an operational temperature range of -40°C to +85°C.
Features
- Up to 12-cell voltage monitors, support Li-Ion CoO2, Li-ion Mn2O4, and Li-ion FePO4 chemistries
- Cell voltage measurement accuracy ±10mV
- 13-bit cell voltage measurement
- Pack voltage measurement accuracy ±180mV
- 14-bit pack voltage and temperature measurements
- Cell voltage scan rate of 19.5µs per cell (234µs to scan 12 cells)
- Internal temperature monitoring
- Up to four external temperature inputs
- Robust daisy chain communications system
- Integrated system diagnostics for all key internal functions
- Hardwired and communications based fault notification
- Integrated watchdog shuts down device if communication is lost
- 7µA shutdown current: Enable = VSS
- 2Mbps SPI
Comparison
Applications
Design & Development
Sample Code
Boards & Kits
Models
ECAD Models
Schematic symbols, PCB footprints, and 3D CAD models from SamacSys can be found by clicking on the CAD Model links in the Product Options table. If a symbol or model isn't available, it can be requested directly from SamacSys.

Support
Support Communities
Support Communities
-
ISL94212
I want ISL94212 Arduino sample code and i am facing issue on hardware side ic not generating input voltage like v2p5 , vref , Exvdd .
May 13, 2023 -
ISL94212 Communication Issue
Hi All, I am trying to interface an Arduino with ISL94212 in daisy chain (3 devices). However, I am facing an error that whenever I read any value such as voltage I always get 0s in the data field. I also tried setting the overvoltage limit register but its data ...
Oct 12, 2020 -
ISL94212 BMS
#DATA READY TIMEOUT AND EEPROM COMM ERROR I am working on ISL94212 BMS and I am using the daisy chain communication because I connected two ISL94212 devices. as for the document I have done the setting. when I am connecting my battery red led glows on ISL94212. I am ...