These MCUs are fabricated using a high-performance silicon gate CMOS process, embedding the R8C CPU core, and are packaged in a 32-pin molded-plastic LQFP. It implements sophisticated instructions for a high level of instruction efficiency. With 1Mb of address space, they are capable of executing instructions at high speed. Furthermore, the R8C/27 Group has on-chip data flash (1KB × 2 blocks). The difference between the R8C/26 Group and R8C/27 Group is only the presence or absence of data flash. Their peripheral functions are the same.
Comparison
Applications
Design & Development
Support
Support Communities
Resources
Support Communities
-
LCD Problem
Hi all, I am using 16*2 LCD in 4bit mode..LCD gets initialised properly when my code runs for the first time after it is downloaded..once i restart the system..my lcd is not getting intialised..rest of the peripherals are working fine..i tried to solve the ...
Oct 6, 2009 -
R8C/27 simple serial programmer tool
Hi there, Is there anyone who knows a simple serial programmer hardware to program r5f21276 Please, if there is anyone who has read through the series, help me I appreciate your work.
Dec 27, 2022
FAQs
-
(R8C) Are there any hardware precautions for accurate A/D conversion?
In order to perform A/D conversion, it is necessary to fully charge the internal capacitor, but if the impedance of the A/D conversion target is high, the discharge and charge will take time and the conversion value will not be accurate. For correct A/D ...
Jun 19, 2006 -
Do I need to rewrite the boot ROM area using MI6C Flash Starter?
Rewriting of the boot ROM area is unnecessary. This is because M3A-0806 performs programming using the standard boot program which was programmed into the boot ROM area when it was shipped. (#104963)
Mar 1, 2005 -
Please tell me how to set the option function register in detail.
There are three methods for setting the option function select register using the C complier package M3T-NC30WA: Using the load module converter (lmc30 -R8C) -OFSREGX (or -PROTECTX) option Using assembler directive command .OFSREG (or .PROTECT) By assembly programming The load module converter option and directive command depend on the ...