RSKM16C6C and External Memory, can't write at odd addresses
... data_FO","data","noalign");}// hardware initialisation called at start/*””FILE COMMENT””******************************* Technical reference data ***** File Name : hwsetup.c* Version : 1.00* Device : M16C/6C (R5F36CAMDFB)* Tool Chain : HEW, NC30 V5.44* H/W Platform : RSKM16C6C* Description : Contains hardware Setup functions******************************************************************************//******************************************************************************* History : 30.10 ...
Dec 13, 2011 -
Compatible type to M30245
Hi.I am looking for a compatible type to the M30245. It sholud mainly be pin compatible.I cant find any information on the status of the M30245 on the renesas homepage.It seems to be a outdated product. The whole Family M16C24 seem to be outdated.Am I right ...
May 15, 2010
FAQs
-
(M16C Family products other than the M32C/80 Series, and the M16C/80 Series) Priority level is "0" + Request bit is "1": Priority level to "7"?
The interrupt will be accepted. Then, the interrupt request bit will be cleared. However, if you use the MOV instruction to change the interrupt priority level, the interrupt request bit may be cleared to "0". The interrupt will not be accepted when the interrupt request bit is cleared at this ...
Feb 14, 2006 -
(M32C/80 Series, M16C/80 Series) Priority level is "0" + Request bit is "1": Priority level to "7"?
The interrupt will be accepted. Then, the interrupt request bit will be cleared. However, if you use the MOV instruction to change the interrupt priority level, the interrupt request bit may be cleared to "0". The interrupt will not be accepted when the interrupt request bit is cleared at this ...
Feb 28, 2012 -
(M16C,M32C) Are there any hardware precautions for accurate A/D conversion?
In order to perform A/D conversion, it is necessary to fully charge the internal capacitor, but if the impedance of the A/D conversion target is high, the discharge and charge will take time and the conversion value will not be accurate. For correct A/D ...
Feb 27, 2012