Skip to main content
NOTICE - The following device(s) are recommended alternatives:

Overview

Description

The 8302 is a low skew, 1-to-2 LVCMOS/LVTTL Fanout Buffer. The 8302 has a single-ended clock input. The single-ended clock input accepts LVCMOS or LVTTL input levels. The 8302 features a pair of LVCMOS/LVTTL outputs. The 8302 is characterized at full 3.3V for input VDD, and mixed 3.3V and 2.5V for output operating supply modes (VDDO). Guaranteed output and part-to-part skew characteristics make the 8302 ideal for clock distribution applications demanding well-defined performance and repeatability.

Features

  • 2 LVCMOS / LVTTL outputs
  • LVCMOS / LVTTL clock input accepts LVCMOS or LVTTL input levels
  • Maximum output frequency: 200MHz
  • Output skew: 25ps (typical)
  • Part-to-part skew: 250ps (typical)
  • Small 8 lead SOIC package saves board space
  • Full 3.3V or 3.3V core, 2.5V supply modes
  • 0°C to 70°C ambient operating temperature
  • Lead-Free package fully RoHS compliant

Comparison

Applications

Documentation

Design & Development

Models

ECAD Models

Schematic symbols, PCB footprints, and 3D CAD models from SamacSys can be found by clicking on the CAD Model links in the Product Options table. If a symbol or model isn't available, it can be requested directly from SamacSys.

Diagram of ECAD Models

Models

Type Title Date
Model - IBIS IBS 306 KB
1 item

Product Options

Applied Filters:

Support

Support Communities

Support Communities

Get quick technical support online from Renesas Engineering Community technical staff.
Browse FAQs

FAQs

Browse our knowledge base of common questions and answers.
Submit a Ticket

Submit a Ticket

Need to ask a technical question or share confidential information?

Support Communities

  1. TraceX reports an error if it opens an empty trace buffer (no captured events)

    Issue – Bug Module(s): TraceX   Description: TraceX reports an error if it opens an empty trace buffer (no events). For example, if the user puts a breakpoint at the top of the application thread entry function TraxeX will not have any data buffered, so an error is reported. Workaround: Do ...

    May 19, 2017
  2. RF Master Tool

    Hi Team, We want to download the "prod_test_580.hex" file on our custom Matherboard for Direct test mode validation. We are using the Smart Snippets tool and RF mster section . When I download the hex file,its said the error, "Timeout: Reset signal not detected for more than ...

    Sep 16, 2019
  3. Android in RZ/G2L issue while booting

    Dear Renesas Team, We have built Android 12 for RZG2L and were able to compile with out errors, have followed below steps for flashing android 12 to eMMC. 1)Flash required srec file. 2)Bootloaders to emmc  sudo ./fastboot oem formatsudo ./fastboot reboot bootloader 3) images to eMMC ...

    Mar 14, 2024
View All Results from Support Communities (16)

FAQs

  1. How to run the "Suspend to RAM"

    ... 27.808896] psci: CPU1 killed. [ 27.810293] CPU2: shutdown [ 27.828905] psci: Retrying again to check for CPU kill [ 27.828909] psci: CPU2 killed. [ 27.830236] CPU3: shutdown [ 27.848890] psci: Retrying again to check for CPU kill [ 27.848894] psci: CPU3 killed. [ 27.856891] CPU4: shutdown [ 27.856897] psci ...

    Mar 18, 2021