Overview
Description
The RRH47000 is a single-channel nondispersive infrared (NDIR) CO2 module featuring a highly accurate sensor for CO2 measurement, along with a world-class humidity and temperature sensor, all in a compact package. This module delivers high performance and complies with various CO2 regulatory standards, including California Title 24 Building Energy Efficiency Standards, RESET, WELL, and ASHRAE.
Features
- Single-channel NDIR CO2 detection
- Measurement range: 0ppm – 5000ppm
- High accuracy with long-term stability: ±75ppm
- Automatic Baseline Calibration (ABC)
- Onboard temperature and relative humidity sensor
- Wide operating range: 0 – 95% RH, -10 °C to +50 °C
- Supply voltage: 4.5V to 5.5V
- Supports I2C and UART communication
- Long lifetime: ≥ 15 years
Comparison
Applications
Documentation
|
|
|
---|---|---|
Type | Title | Date |
Datasheet | PDF 878 KB | |
End Of Life Notice | PDF 748 KB | |
2 items
|
Design & Development
Support
Support Communities
Support Communities
-
ZMOD4410 testing conditions and environment compensation
dear team, thanks for a promising product so far. my goal is to determine human presence in the room using co2 as a proxy. This is why i'm interested in the eCO2 from ZMOD 4410. I Understand the gas sensor is not an NDIR CO2 sensor and will not ...
Nov 25, 2024
FAQs
-
RRH47000 - NDIR technology and other CO2 detection technologies
A Nondispersive Infrared (NDIR) sensor is a type of spectroscopic sensor which does not use dispersive elements for separating the target spectrum for sensing from broadband light. 1. NDIR CO₂ SensorsMechanism: Measures CO₂ by analyzing the absorption of infrared light, as CO₂ molecules absorb a specific IR wavelength.Advantages:High ...
Nov 19, 2024 -
RRH47000 - ABC algorithm
Rough handling, sensor aging, and drastic environmental changes may cause a reduction in accuracy. The sensor incorporates an auto-baseline correction (ABC) feature to automatically compensate for drift. The feature operates as follows:• Initial Baseline Correction: After the sensor is powered on, it continuously monitors the CO2 levels for 24 ...
Nov 19, 2024 -
RRH47000 - A recommendation for a basic sensor testing
Example - Read the device serial number via I2C: • connect the module to the host controller according to the datasheet reference (Sec. 7.2.1)• send the device I2C address (0x31) followed by the command byte to retrieve the serial number (0x1F)• make sure the checksum corresponds with the received Byte ...
Nov 18, 2024