Overview
Description
The RH850/P1M-E Group of high-end MCUs are designed specifically for electronic power steering systems and supports the new CAN-FD communication standard.
Features
- CPU: G3M core, Max. 160MHz
- Voltage: 3V to 5.5V
- Package: 100 to 144-pin LFQFP
- Memory: SRAM Max. 192KB, Program Flash Max. 2MB
- Timer: 32-bit Timer (ch) x 12, 16-bit Timer (ch) x 48, Watchdog Timer (ch) x 1, TSG3 x2unit, ENCA x2unit, OSTM x7unit, TPBA x2unit
- PWM: PWM Output x 32, 3-phase PWM Output Function
- Analog function: 12-bit A/D Converter (ch) x 24
- On-chip Oscillator Freq. (MHz): 8 MHz
- Others: PLL, Power-On Reset
Comparison
Applications
Design & Development
Software & Tools
Sample Code
Boards & Kits
Models
ECAD Models
Schematic symbols, PCB footprints, and 3D CAD models from SamacSys can be found by clicking on the CAD Model links in the Product Options table. If a symbol or model isn't available, it can be requested directly from SamacSys.

Support
Support Communities
Resources
Support Communities
-
RH850/P1M-E RSCAN Tx History Buffer Configuration
Hi, I'm using CAN0 and Have configured Tx buffers(10 buffers) for Transmission and its working fine. But I need to utilize CAN Tx history buffer to get the transmitted data info. I couldn't able to set RSCANnTHLCCm bitfield THLE to 1 to enable the history buffer. Can ...
May 21, 2025 -
Pin Mapping Tool for RH850/P1M-E
Hello, Is there a pin mapping tool for the RH850/P1M-E series MCU?
May 26, 2025 -
Code Flash ECC error triggered unexpectedly even after being disabled and ECC IRQ configuration questions
Hello everyone, I am implementing code flash CRC check feature for RH850/P1M-E at program startup. Firstly, by configuring CS+ IDE to calculate calculated CRC place to address of main Code Flash area (0x001FFFF0). CS+ setting is: 001FFFF0=00000000-001FFFE0/CCITT:LITTLE-4-0 In the program ...
Mar 27, 2025
FAQs
-
Software protection of flash memory on some RH850 devices
Last updated: 10/7/2025 Question: Is there any software protection of flash memory on RH850 devices ? Answer: The following RH850 devices have a software protection mechanism of flash memory: RH850/P1L-C RH850/P1M-E RH850/P1M-C RH850/C1M-A RH850/ ...
Jan 1, 1970 -
The Information Obtained with the Communication Command "gos" (PG-FP6, PG-FP5)
The following is the information collected from the RH850/P1M-E by the "gos" command, information format, and the meanings.・Blank check: CF1: Code flash 1 blank check result CF2: Code flash 2 blank check result UB: User boot blank check result DF: Data flash blank check result・Option ...
Feb 1, 2022