I need help, please
... device and show some results on the TFT-LCD panel with touch screen. The problem I have is that there is a pin conflict on H8S/2456 RSK ( LCD direct drive TPU and SSU module). The way I normally solve the problem is: 1.- EXDMA module off 2.- TPU ...
Jan 31, 2011 -
LCD Screen Home Handler
In the LCD Evaluation Kit for H8S/2456, there are several symbolic constants available to manage the screen stack: MSG_SCREEN_CHANGE, MSG_SCREEN_PUSH and MSG_SCREEN_POP. Unfortunately, there is no direct support for jumping all the way back to "Home" -- important in applications that have a ...
Dec 6, 2012
FAQs
-
(H8S) Is it possible to set φ output pin as I/O port output pin?
No. φ output pin cannot be set as I/O port output pin. (There is no alternative settings.)
Dec 25, 2008 -
If I access embedded ROM, is the address signal output from address bus?
No. If you access embedded ROM, embedded RAM or I/O register, the status of previous external access is kept.
Dec 25, 2008 -
If SCI is enabled by external clock, does SCR be set for external clock?
No. In case of synchronized external clock input, CKE bit of BRR or SCR doesn't need to be set for either transmit/receive operation.