Overview
Description
The Intersil CD22M3494 is an array of 128 analog switches capable of handling signals from DC to video. Because of the switch structure, input signals may swing through the total supply voltage range, VDD to VEE. Each of the 128 switches may be addressed via the ADDRESS input to the 7 to 128 line decoder. The state of the addressed switch is established by the signal to the DATA input. A low or zero input will open the switch, while a high logic level or a one will result in closure of the addressed switch when the STROBE input goes high from its normally low state. Any number or combination of connections may be active at one time. Each connection, however, must be made or broken individually in the manner previously described. All switches may be reset by taking the RESET input from a zero state to a one state and then returning it to its normal low state. CS allows crosspoint array to be cascaded for matrix expansion.
Features
- 128 Analog Switches
- Low rON
- Guaranteed rON Matching
- Analog Signal Input Voltage Equal to the Supply Voltage
- Wide Operating Voltage: 4V to 15V
- Parallel Input Addressing
- High Latch-Up Current: 50mA (Min)
- Very Low Crosstalk
- Pin and Functionally Compatible with the Following Types: SGS M3494 and Mitel MT8816
- Pb-Free (RoHS Compliant)
Comparison
Applications
Documentation
|
|
|
---|---|---|
Type | Title | Date |
Datasheet | PDF 900 KB | |
Price Increase Notice | PDF 208 KB | |
End Of Life Notice | PDF 388 KB | |
End Of Life Notice | PDF 345 KB | |
Product Change Notice | PDF 86 KB | |
5 items
|
Design & Development
Models
ECAD Models
Schematic symbols, PCB footprints, and 3D CAD models from SamacSys can be found by clicking on the CAD Model links in the Product Options table. If a symbol or model isn't available, it can be requested directly from SamacSys.

Support
Support Communities
Support Communities
-
Cd22m3494ezr5276 and cd22m3494ez,What's the difference between these two models?
Cd22m3494ezr5276 and cd22m3494ez help to see what r5276 means? What's the difference between these two models?
Jun 1, 2021
FAQs
-
What is the difference between CD22M3494MQZ and CD22M3494MQAZ?
Question:1. What is the difference between CD22M3494MQZ and CD22M3494MQAZ? 2. What does 'A' Suffix mean? Answer:The 'A' suffix was generated to denote the modified CD22M3494 which had the improved latch-up spec. The change was incorporated into the non "A" parts in 9-27-1993. Since we had ...
Jan 1, 1970 -
Can we use 12V supply for Vdd and 5V logic on the CD22M3494?
Question:We are using the CD22M3494 with 12V supply for Vdd, and 5V logic for driving the control and address lines. Can this usage cause any problems such as over-current, damage to a device, etc.? Answer: It is OK to have Vdd at 12V and to drive the control ...
Jan 1, 1970 -
For the CD22M3494, what are the digital input VIH and VIL when VDD=15V (Vss=Vee=GND)?
Question:What are the digital input VIH and VIL when VDD=15V (Vss=Vee=GND)? The datasheet specifies VIH and VIL when VDD=5V, but does not provide values if VDD=15V. Answer:Typical VIH and VIL vs. VDD are shown below. VDD VIH VIL 5 1.5V 1.4V ...