Image
Akihiro Ooshima
Akihiro Ooshima
Engineer

The structure of sensor device can be roughly categorized into 2 types and from time to time, which type to be adopted to the application requires thorough consideration. 

  • Separated structure: Sensor and signal conditioner are in separate housings, connected to each other by wire harness.
  • Integrated structure: Sensor and signal conditioner are integrated in the same housing.
Image
RX23E-A structure en

 

Lately, the demand for small sensor has increased so that the adoption of integrated structure has been apparently expanding. Load cell application is no exception to the trend. Digital load cell, which outputs digital signal and houses both sensor and signal conditioner, is becoming widely deployed.
The advantage of the integrated sensor structure is the improved in precision of measurement and noise immunity due to signal is being Conditioned and processed closely to sensor. On the other hand, the integrated structure poses a difficulty to implement all required functions, such as analog parts, ADC, and MCU in a constrained space. It is quite often that the mounting area is only enough for an analog part such as amplifier, and MCU and ADC have to be implemented in another housing.
In such a case, RX23E-A, with high precision 24-bit ΔΣ ADC, built-in PGA and MCU on a single chip in a small package, appears to be the best option against this challenge. 
Renesas has developed a RX23E-A reference design of on a tiny board for digital load cell as a proof of addressing this challenge.
 

Image
RX23E-A coin and board
Image
RX23E-A measure and board

 

The board is 22mm×16mm in size with RX23E-A MCU and ISL3152 RS-485/RS-422 transceiver mounted. The RX23E-A performs A/D conversion, digital filter processing, calibration, and conversion of physical quantity (Voltage to Weight), while the ISL3152E transmits the converted weight values to host devices with digital communication.

Image
RX23E-A circuit

 

We have done the evaluation of weight measurement by incorporating this small board into a load cell and confirmed that non-linear errors of the weight measurement are within ±0.01% max span. As a result, it is considered that the performance of a general load cell can be fully demonstrated.

Image
RX23E-A graph

 

The reference design is described in detail in the Application Note:” RX23E-A QFN40W/T Tiny Board for Digital Load Cell” (Document No. R12AN0114EJ0100). It is also introduced on the specific web page below. Feel free to check it out in the link below.

Link: RX23-E-A Tiny Board forDigital Loadcell Reference Design

Share this news on

Log in or register to post comments