Overview

Description

The Renesas ISL317xE are ±15kV IEC61000 ESD protected, 3. 3V powered single transceivers that meet both the RS-485 and RS-422 standards for balanced communication. These devices have very low bus currents (+125µA/-100µA), so they present a true “1/8 unit load” to the RS-485 bus. This allows up to 256 transceivers on the network without violating the RS-485 specification's 32 unit load maximum, and without using repeaters. For example, in a remote utility meter reading system, individual meter readings are routed to a concentrator using an RS-485 network, so the high allowed node count minimizes the number of repeaters required. Receiver (Rx) inputs feature a “Full Fail-Safe” design, which ensures a logic high Rx output if Rx inputs are floating, shorted, or terminated but undriven. Hot Plug circuitry ensures that the Tx and Rx outputs remain in a high impedance state while the power supply stabilizes. The ISL3170E through ISL3175E utilize slew rate limited drivers which reduce EMI, and minimize reflections from improperly terminated transmission lines, or unterminated stubs in multidrop and multipoint applications. Slew rate limited versions also include receiver input filtering to enhance noise immunity in the presence of slow input signals. The ISL3170E, ISL3171E, ISL3173E, ISL3174E, ISL3176E, and ISL3177E are configured for full duplex (separate Rx input and Tx output pins) applications. The half duplex versions multiplex the Rx inputs and Tx outputs to allow transceivers with output disable functions in 8 Ld packages.

Features

  • IEC61000 ESD protection on RS-485 I/O pins ±15kV
    • Class 3 ESD level on all other pins >7kV HBM
  • Full fail-safe (open, short, terminated/floating) receivers
  • Hot plug - Tx and Rx outputs remain three-state during power-up (only versions with output enable pins)
  • True 1/8 unit load allows up to 256 devices on the bus
  • Single 3.3V supply
  • High data rates up to 20Mbps
  • Low quiescent supply current 800µA (Max)
    • Ultra low shutdown supply current 10nA
  • -7V to +12V common-mode input/output voltage range
  • Half and full duplex pinouts
  • Three state Rx and Tx outputs available
  • Current limiting and thermal shutdown for driver overload protection
  • Tiny MSOP packages consume 50% less board space
  • Pb-free (RoHS compliant)

Comparison

Applications

Applications

  • Automated utility meter reading systems
  • High node count systems
  • Field bus networks
  • Security camera networks
  • Building environmental control/lighting systems
  • Industrial/process control networks

Documentation

Type Title Date
Datasheet PDF 1.38 MB
Training PDF 762 KB
Brochure PDF 5.20 MB 日本語
Training PDF 208 KB
Brochure PDF 2.95 MB
Training PDF 405 KB
Training PDF 239 KB
Technical Brief PDF 266 KB 简体中文
Application Note PDF 365 KB
Application Note PDF 207 KB
Application Note PDF 474 KB
Product Advisory PDF 203 KB
Product Change Notice PDF 178 KB
Application Note PDF 366 KB
Technical Brief PDF 188 KB
Report PDF 438 KB
Product Change Notice PDF 266 KB
Application Note PDF 178 KB
Price Increase Notice PDF 208 KB
Other PDF 156 KB
White Paper PDF 920 KB 简体中文
White Paper PDF 246 KB 简体中文
Application Note PDF 513 KB
Application Note PDF 826 KB
Other PDF 253 KB
Application Note PDF 443 KB
Application Note PDF 582 KB
Application Note PDF 440 KB
Product Advisory PDF 106 KB
Product Change Notice PDF 294 KB
Product Change Notice PDF 108 KB
Application Note PDF 338 KB
Application Note PDF 365 KB
Application Note PDF 375 KB
Other PDF 254 KB
Application Note PDF 559 KB
36 items

Design & Development

Models

Models

Type Title Date
Model - IBIS IBS 45 KB
Model - IBIS IBS 45 KB
2 items

Support